CONTENTS

The Start Manager was revised in Mac OS 8.1 to add a mechanism for monitoring and controlling the loading of system extensions during system startup.

This Technote describes how the Start Manager was changed, and shows how a program can monitor or take control of the system extension loading process.

 Updated: [Apr 15 1998]






Introduction

Prior to Mac OS 8.1, system extensions were loaded and executed from three folders in order: the Extensions folder, Control Panels folder, and the System Folder. The system extensions in each folder were loaded and executed in the order they were found on the disk. On an HFS volume (also known as Mac OS Standard) item names are stored using ASCII characters. Items are stored in the catalog file in RelString order, i.e., in the order the names would be in if sorted by the RelString function. Because of this, the File Manager's GetFInfo routine returns files in RelString order.

With the introduction of Mac OS 8.1, a new bootable disk format, HFS Plus (also known as Mac OS Extended), was introduced. On HFS Plus volumes item names are stored using Unicode, rather than ASCII characters. Items are stored in the catalog file in a different order than they would be on an HFS volume. Details on the sorting order for HFS Plus volumes can be found in the HFS Plus Volume Format documentation.



Note:
Applications should never rely on the order in which files are stored on a volume. Each volume format is free to sort item in any order, or to not sort items at all.



On systems using the Roman script system, files on HFS Plus volumes are returned by GetFInfo in a similar, but not exactly the same, order as RelString. However, on systems running non-Roman script systems, GetFInfo may return files in a radically different order.



Note:
Apple has always maintained that system extensions cannot depend on a particular load order; however, many system extensions do require specific loading orders.



To prevent problems for our users, and to ensure that system extensions load and execute in the same order regardless of the volume format and script system used, the system extension mechanism was revised to be table driven. The Start Manager builds a single table of system extensions, sorted using RelString, from the system extensions found in each folder. Then, each system extension is loaded and executed, in order, from the table. The result is that system extensions are loaded and executed in the same order regardless of which type of volume the system is booting from and what script system the system is running.

The Start Manager was revised to allow other programs access to the system extension loading mechanism. Programs can either monitor or control the system extension loading and execution process.

Monitor and Control

A program can install an ExtensionNotificationProc to monitor the system extension loading process. Each ExtensionNotificationProc is called before the first system extension is loaded and executed, both before and after each system extension is loaded and executed, and after the last system extension is loaded and executed. When called, an extension notification routine can perform some action such as drawing an icon, playing a sound, displaying the system extension's name, or saving the system extension's name in a file to help debug system extension crashes or document system extension loading order. An ExtensionNotificationProc cannot change the order that system extensions load and execute. Any number of ExtensionNotificationProcs can be installed.

A program can install an ExtensionTableHandlerProc to control the system extension loading process. The ExtensionTableHandlerProc is called before the first system extension is loaded and executed, both before and after each system extension is loaded and executed, and after the last system extension is loaded and executed. Unlike an ExtensionNotificationProc, the ExtensionTableHandlerProc owns the extension table and has complete control over the order that system extensions load and execute. A program that installs an ExtensionTableHandlerProc can also prevent some system extensions from loading and load system extensions from other than the default folders. Only one ExtensionTableHandlerProc can be installed.

If no ExtensionTableHandlerProc is installed, the Start Manager uses its own default extension table handler. This default extension table handler mimics the behavior of the File Manager under previous versions of Mac OS (i.e., if the contents of a folder used to build the extension table changes, then the extension table is rebuilt and execution is resumed where it would have if the Start Manager were calling GetFInfo).



Note:
An ExtensionNotificationProc or ExtensionTableHandlerProc can be installed at any point in the startup process and will begin receiving messages from that point forward. An ExtensionTableHandlerProc can control the loading and execution of system extensions that have not already been installed.



The Extension Table

The extension table is a relocatable block in the system heap containing an ExtensionTable structure. An ExtensionTable consists of an ExtensionTableHeader followed by an array of ExtensionElements. The ExtensionTableHeader contains the version field which indicates the version of both the ExtensionTable and the ExtensionElement records, an index into the ExtensionElements which indicates which system extension is currently loading and executing, the size of an ExtensionElement, and the number of ExtensionElements in the table. Each ExtensionElement in the ExtensionTable contains information used to identify which system extensions will be loaded and executed by the Start Manager.

Each installed ExtensionNotificationProc will be passed a copy of the ExtensionElement for the system extension which is currently being loaded and executed.

The ExtensionTableHandlerProc controlling the system extension loading process will be passed the ExtensionTable each time it is called. This handler can control the loading of system extensions by modifying the ExtensionTable.

The Boot Process

The Start Manager installs the APIs for installing and removing ExtensionTableHandlerProc and ExtensionNotificationProcs early in the boot process (after MacsBug has loaded but before MacsBug dcmdSecondaryINIT time).

Before system extensions are to be loaded and executed, the Start Manager creates an extension table.

Before the first system extension is loaded and executed, the ExtensionTableHandlerProc and each ExtensionNotificationProc will be called with the extNotificationBeforeFirst message indicating that the system extension loading process is about to begin. The ExtensionTableHandlerProc is always called with the extNotificationBeforeFirst message before any ExtensionNotificationProc.

The Start Manager then loads and executes each system extension in order from the extension table. Before each system extension is loaded and executed, the ExtensionTableHandlerProc and all ExtensionNotificationProcs are called with the extNotificationBeforeCurrent message. After each system extension is loaded and executed, all ExtensionNotificationProcs and the ExtensionTableHandlerProc are called with the extNotificationAfterCurrent message. The ExtensionTableHandlerProc is always called with the extNotificationBeforeCurrent message before any ExtensionNotificationProcs, and the ExtensionTableHandlerProc is always called with the extNotificationAfterCurrent message after any ExtensionNotificationProcs.

After all system extensions have been loaded all ExtensionNotificationProcs and the ExtensionTableHandlerProc are called with the extNotificationAfterLast message indicating that the system extension loading process is complete. The ExtensionTableHandlerProc is always called with the extNotificationAfterLast message after the last ExtensionNotificationProc.

In all cases, the relative order in which ExtensionNotificationProcs are called is not defined.

Monitoring System Extension Loading

An INIT, or a program executed before system extensions are loaded, can monitor the system extension loading process by calling InstallExtensionNotificationProc to install an ExtensionNotificationProc. Once installed, this handler will be called:

  • Before the first system extension is loaded and executed (if installed before the system extension load and execute process).
  • Before each system extension is loaded and executed.
  • After each system extension has been loaded and executed.
  • After the last system extension has been loaded and executed.

An ExtensionNotificationProc receives an ExtensionElementPtr which points to a copy of the ExtensionElement for the system extension currently being loaded.



Note:
The data in the ExtensionElement is read-only. While you can change it, you'll only be changing a copy of the ExtensionElement. Any changes will be discarded when the ExtensionNotificationProc returns.



There can be any number of ExtensionNotificationProcs installed.


Controlling System Extension Loading

An INIT, or a program executed before system extensions are loaded, can take control of the system extension loading process by calling InstallExtensionTableHandlerProc to install a ExtensionTableHandlerProc. InstallExtensionTableHandlerProc returns the default ExtensionTable created by the Start Manager.

There can only be one ExtensionTableHandlerProc installed.

While it is installed, the ExtensionTableHandlerProc is responsible for all changes to the ExtensionTable, except for incrementing extElementIndex field between system extensions. After an ExtensionTableHandlerProc is installed, the system's default extension table handler no longer manages the ExtensionTable.

Once installed, the ExtensionTableHandlerProc will be called:

  • Before the first system extension is loaded and executed (if installed before the system extension load and execute process).
  • Before each system extension is loaded and executed.
  • After each system extension has been loaded and executed.
  • After the last system extension has been loaded and executed.

Unlike ExtensionNotificationProcs, the ExtensionTableHandlerProc receives a handle to the ExtensionTable used by the Start Manager -- not a copy.



Note:
Once an installed ExtensionTableHandlerProc modifies the ExtensionTable, or the contents of the folders controlled in the ExtensionTable are changed, the handler cannot be removed. Calling RemoveExtensionTableHandlerProc after these changes will return a paramErr error.



The extElementIndex field in the ExtensionTable is always incremented to the next ExtensionElement immediately after the ExtensionTableHandlerProc is called with the extNotificationAfterCurrent message.



IMPORTANT:
When controlling the loading of system extensions, the only safe time to change which ExtensionElement is at ExtensionTable.extElements[extElementIndex] is when your ExtensionTableHandlerProc is called with the extNotificationAfterCurrent message. You may change the ExtensionTable or the extElementIndex at other times, but you must ensure that the ExtensionElement at ExtensionTable.extElements[extElementIndex] stays the same.




Extension Table Manager Reference

This section discusses the techniques you can use to monitor or control the system extension loading and execution process.

Extension Table Version (Gestalt)

You should call Gestalt with the gestaltExtensionTableVersion selector to determine the version of ExtensionTable currently installed before installing any handlers for the extension table mechanism.



enum {
    gestaltExtensionTableVersion = FOUR_CHAR_CODE('etbl') /* ExtensionTable version */
};


The current (Mac OS 8.1) ExtensionTable version is 1.0.0.



enum {
    kExtensionTableVersion = 0x00000100  /* current ExtensionTable version (1.0.0) */
};


If gestaltExtensionTableVersion is not defined, it indicates that there is no extension table mechanism present and that the associated extension table routines will be undefined.

When the major version number of kExtensionTableVersion and the value returned by gestaltExtensionTableVersion are different, it indicates that the extension table mechanism has radically changed and code that doesn't know about the new major version must not attempt to use the extension table mechanism.

Changes to the minor version number of kExtensionTableVersion indicate that the definition of the ExtensionElement structure has been extended, but the fields defined for previous minor versions of kExtensionTableVersion have not changed.

ExtensionTable Structure

An ExtensionTable is an ExtensionTableHeader followed by an array of ExtensionElements. This structure is built by the extension table mechanism when it scans for system extensions to be loaded and executed at boot time.



struct ExtensionTable {
    ExtensionTableHeader     extTableHeader; /* the ExtensionTableHeader */
    ExtensionElement         extElements[1]; /* one element for each extension to load */
};
typedef struct ExtensionTable    ExtensionTable;
typedef        ExtensionTable    * ExtensionTablePtr;
typedef        ExtensionTablePtr * ExtensionTableHandle;


An ExtensionTableHandle containing the current ExtensionTable will be passed as a parameter to the installed ExtensionTableHandlerProc when it is called.

ExtensionTableHeader Structure

An ExtensionTable begins with an ExtensionTableHeader.



struct ExtensionTableHeader {
    UInt32    extTableHeaderSize;
    UInt32    extTableVersion;
    UInt32    extElementIndex;
    UInt32    extElementSize;
    UInt32    extElementCount;
};
typedef struct ExtensionTableHeader ExtensionTableHeader;


extTableHeaderSize

The size of ExtensionTableHeader. Equal to offsetof(ExtensionTable,extElements[0])

extTableVersion

The current ExtensionTable version. The same as the value returned by gestaltExtensionTableVersion Gestalt selector

extElementIndex

The current index into ExtensionElement[] (zero-based). Incremented by the Start Manager after each system extension is loaded and executed

extElementSize

The size of the ExtensionElements in this version of the ExtensionTable

extElementCount

The number of ExtensionElement records in the ExtensionTable

The ExtensionTableHandlerProc should check the minor version of the extTableVersion field. If it has changed since the ExtensionTableHandlerProc was written, it indicates that the value of extElementSize will be larger. If the ExtensionTableHandlerProc is only moving and deleting elements in the table it could continue to run. However, if it wants to create new elements, it should remove itself because it will not know how to create the new fields in the ExtensionElements.

This structure is used internally by the Start Manager, and is passed to the installed ExtensionTableHandlerProc each time it is called.

ExtensionElement Structure

The ExtensionElement structure is used to hold information about each system extension that the Start Manager will load and execute.



struct ExtensionElement {
    Str31               fileName;         /* The file name */
    long                parentDirID;      /* the file's parent directory ID */
      /* everything after ioNamePtr in the HParamBlockRec.fileParam variant */
    short               ioVRefNum;        /* always the real volume reference number*/
                                          /* (not a drive, default, or working dirID) */
    short               ioFRefNum;
    SInt8               ioFVersNum;
    SInt8               filler1;
    short               ioFDirIndex;      /* always 0 in table */
    SInt8               ioFlAttrib;
    SInt8               ioFlVersNum;
    FInfo               ioFlFndrInfo;
    long                ioDirID;
    unsigned short      ioFlStBlk;
    long                ioFlLgLen;
    long                ioFlPyLen;
    unsigned short      ioFlRStBlk;
    long                ioFlRLgLen;
    long                ioFlRPyLen;
    unsigned long       ioFlCrDat;
    unsigned long       ioFlMdDat;
};
typedef struct ExtensionElement         ExtensionElement;
typedef ExtensionElement *              ExtensionElementPtr;


The first two elements identify the individual file, while the rest of the elements are copied directly from the fileParam variant of the HParamBlockRec.

An ExtensionElement is created for each system extension found by the Start Manager in the Extensions folder, Control Panels folder, and System Folder. These ExtensionElements are collected into a ExtensionTable.

An ExtensionElementPtr is passed as a parameter to each installed ExtensionNotificationProc when it is called. The ExtensionElement it points to will contain a copy of the ExtensionElement for the system extension that is currently being loaded and executed.

Extension Notification Message Codes

When an ExtensionNotificationProc or ExtensionTableHandlerProc is called, it will be passed a message parameter containing one of the following values.



enum {
    extNotificationBeforeFirst   = 0, /* Before any system extensions have loaded */
    extNotificationAfterLast     = 1, /* After all system extensions have loaded */
    extNotificationBeforeCurrent = 2, /* Before system extension at */
                                      /* extElementIndex is loaded */
    extNotificationAfterCurrent  = 3  /* After system extension at */
                                      /* extElementIndex is loaded */
};


ExtensionNotificationProc



pascal void MyExtensionNotificationProc( UInt32 message, void *reserved,
                                         ExtensionElementPtr extElement );


message

input

One of the 4 defined ExtensionNotification message codes

reserved

Reserved for future use

extElement

input

Copy of the ExtensionElement for the system extension currently being loaded and executed



Note:
extElement is not valid for the extNotificationBeforeFirst and extNotificationAfterLast messages.



An ExtensionNotificationProc receives an ExtensionElementPtr which points to a copy of the ExtensionElement for the system extension currently being loaded.



Note:
The data in the ExtensionElement is read-only. While you can change it, you'll only be changing a copy of the ExtensionElement. Any changes will be discarded when the ExtensionNotificationProc returns.



There can be any number of ExtensionNotificationProcs installed.



Note:
An ExtensionNotificationProc cannot call RemoveExtensionNotificationProc. If there is a need for an ExtensionNotificationProc to remove itself, the removal must be deferred by, for example, installing a Notification Manager task and using the notification task to remove the ExtensionNotificationProc.



ExtensionTableHandlerProc



pascal void MyExtensionTableHandlerProc( UInt32 message, void *reserved,
                                         ExtensionTableHandle extTableHandle );


message

input

One of the 4 defined ExtensionNotification message codes

reserved

Reserved for future use

extTableHandle

input

ExtensionTableHandle containing all system extensions to be loaded

An ExtensionTableHandlerProc receives a handle to the ExtensionTable created at startup by the Start Manager. When an ExtensionTableHandlerProc is installed, the system's default handler no longer manages the ExtensionTable. While it is installed, the ExtensionTableHandlerProc is responsible for all changes to the ExtensionTable, except for incrementing extElementIndex between system extensions.



Note:
If the ExtensionTable or the contents of the folders included in the ExtensionTable are changed after installing an ExtensionTableHandlerProc, RemoveExtensionTableHandlerProc cannot be called.



The extElementIndex field is always incremented to point to the next system extension to be loaded immediately after the ExtensionTableHandlerProc is called with the extNotificationAfterCurrent message.



IMPORTANT:
When controlling the loading of system extensions, the only safe time to change which ExtensionElement is at ExtensionTable.extElements[extElementIndex] is when your ExtensionTableHandlerProc is called with the extNotificationAfterCurrent message. You may change the ExtensionTable or the extElementIndex at other times, but you must ensure that the ExtensionElement at ExtensionTable.extElements[extElementIndex] stays the same.



The installed ExtensionTableHandlerProc is always the first handler called with extNotificationBeforeFirst and extNotificationBeforeCurrent messages and the last handler called with extNotificationAfterLast and extNotificationAfterCurrent messages.

There can only be one ExtensionTableHandlerProc installed.

InstallExtensionNotificationProc



OSErr InstallExtensionNotificationProc( ExtensionNotificationUPP extNotificationProc )


Parameters:

extNotificationProc

input

The ExtensionNotificationUPP to install

Results:

noErr

0

The ExtensionNotificationUPP was installed

paramErr

-50

This ExtensionNotificationUPP has already been installed

memFullErr

-108

Not enough memory to install the ExtensionNotificationUPP

Installs an ExtensionNotificationUPP.

Multiple ExtensionNotificationProcs may be installed.

RemoveExtensionNotificationProc



OSErr RemoveExtensionNotificationProc (ExtensionNotificationUPP
                                       extNotificationProc)


Parameters:

extNotificationProc

input

The ExtensionNotificationUPP to remove

Results:

noErr

0

The ExtensionNotificationUPP was installed

paramErr

-50

This ExtensionNotificationUPP was not found, or RemoveExtensionNotificationProc was called from within a ExtensionNotificationProc

Removes an ExtensionNotificationUPP.



Note:
ExtensionNotificationProcs cannot call RemoveExtensionNotificationProc.



InstallExtensionTableHandlerProc



OSErr InstallExtensionTableHandlerProc( ExtensionTableHandlerUPP extMgrProc,
                                        ExtensionTableHandle * extTable)


Parameters:

extMgrProc

input

The ExtensionTableHandlerUPP to install

extTable

input

A pointer to an ExtensionTableHandle where InstallExtensionTableHandlerProc will return the current ExtensionTableHandle. You don't own the handle itself and must not dispose of it, but you can change the extElementIndex. the extElementCount, and the ExtensionElements in the table.

Results:

noErr

0

The ExtensionTableHandlerUPP was installed

paramErr

-50

Another ExtensionTableHandlerUPP has already been installed

memFullErr

-108

Not enough memory to install the ExtensionTableHandlerUPP

Installs an ExtensionTableHandlerUPP.

There can only be one ExtensionTableHandlerProc installed.

RemoveExtensionTableHandlerProc



OSErr RemoveExtensionTableHandlerProc( ExtensionTableHandlerUPP extMgrProc )


Parameters:

extMgrProc

input

The ExtensionTableHandlerUPP to remove

Results:

noErr

0

The ExtensionTableHandlerUPP was removed

paramErr

-50

This ExtensionTableHandlerUPP was not installed,
or the ExtensionTable no longer matches
the original ExtensionTable.

Remove an ExtensionTableHandlerUPP. Control is passed back to the default handler.



Note:
If the ExtensionTable or the contents of the folders included in the ExtensionTable are changed after installing an ExtensionTableHandlerProc, RemoveExtensionTableHandlerProc cannot be called.



Summary of the Extension Table Manager



Note:
All definitions in this section are available in Universal Interfaces 3.1.



Constants



enum {
    gestaltExtensionTableVersion = FOUR_CHAR_CODE('etbl')  /* ExtensionTable version */
};

enum {
    kExtensionTableVersion      = 0x00000100  /* current ExtensionTable version (1.0.0) */
};

/* ExtensionNotification message codes */

enum {
    extNotificationBeforeFirst  = 0,  /* Before any system extensions have loaded */
    extNotificationAfterLast    = 1,  /* After all system extensions have loaded */
    extNotificationBeforeCurrent = 2, /* Before system extension at */
                                      /* extElementIndex is loaded */
    extNotificationAfterCurrent = 3   /* After system extension at */
                                      /* extElementIndex is loaded */
};


Data Types



struct ExtensionElement {
    Str31               fileName;          /* The file name */
    long                parentDirID;       /* the file's parent directory ID */
                                           /* and everything after ioNamePtr */
                                           /* in the HParamBlockRec.fileParam variant */
    short               ioVRefNum;         /* always the real volume reference number */
                                           /* (not a drive, default, or working dirID) */
    short               ioFRefNum;
    SInt8               ioFVersNum;
    SInt8               filler1;
    short               ioFDirIndex;       /* always 0 in table */
    SInt8               ioFlAttrib;
    SInt8               ioFlVersNum;
    FInfo               ioFlFndrInfo;
    long                ioDirID;
    unsigned short      ioFlStBlk;
    long                ioFlLgLen;
    long                ioFlPyLen;
    unsigned short      ioFlRStBlk;
    long                ioFlRLgLen;
    long                ioFlRPyLen;
    unsigned long       ioFlCrDat;
    unsigned long       ioFlMdDat;
};
typedef struct ExtensionElement         ExtensionElement;
typedef ExtensionElement *              ExtensionElementPtr;

struct ExtensionTableHeader {
    UInt32    extTableHeaderSize;    /* size of ExtensionTable header ( equal to */
                                     /* offsetof(ExtensionTable, extElements[0])) */
    UInt32    extTableVersion;       /* current ExtensionTable version (same as */
                                     /* returned by gestaltExtensionTableVersion) */
    UInt32    extElementIndex;       /* current index into ExtensionElement records */
                                     /* (zero-based) */
    UInt32    extElementSize;        /* size of ExtensionElement */
    UInt32    extElementCount;       /* number of ExtensionElement records */
                                     /* in table (1-based) */
};

typedef struct ExtensionTableHeader     ExtensionTableHeader;

struct ExtensionTable {
    ExtensionTableHeader   extTableHeader;          /* the ExtensionTableHeader */
    ExtensionElement       extElements[1];  /* 1 element per system ext. to load */
};
typedef struct ExtensionTable           ExtensionTable;
typedef ExtensionTable *                ExtensionTablePtr;
typedef ExtensionTablePtr *             ExtensionTableHandle;


Routines



OSErr   InstallExtensionNotificationProc( ExtensionNotificationUPP  extNotificationProc)

OSErr   RemoveExtensionNotificationProc( ExtensionNotificationUPP  extNotificationProc)

OSErr   InstallExtensionTableHandlerProc( ExtensionTableHandlerUPP  extMgrProc,
                                          ExtensionTableHandle *    extTable)

OSErr   RemoveExtensionTableHandlerProc( ExtensionTableHandlerUPP  extMgrProc )


Result Codes



noErr          0   The ExtensionNotificationUPP was removed.

paramErr     -50   An error in the parameters prevented the
                   normal execution of the routine.

memFullErr  -108   Not enough memory to install the
                   ExtensionTableHandlerUPP.



Back to top